if I do a -HUP to the shadow's won't that restart other things?
I am always worried about restarting stuff on condor. Is there a table
in the manual that shows what is safe to restart and what isn't?
On Thu, Nov 5, 2009 at 10:09 AM, Dan Bradley <dan@xxxxxxxxxxxx> wrote:
Todd Tannenbaum wrote:
Steven Timm wrote:
system_periodic_hold is executed on the machine that reruns
the condor_schedd. I think you have to restart the condor_schedd.
Steve
Restarting the schedd will certainly work, but a reconfig is all that is
required. So you could reconfigure "on the fly" by making the change in
the config file and then doing
condor_reconfig <name of submit machine>
from a machine with ADMINISTRATOR authorization according to the config
file (by default this means the central manager).
That's true for idle jobs but not for running jobs. (Perhaps this is an
oversight.)
The workaround is to send SIGHUP to all running shadows in addition to
running condor_reconfig.
--Dan