I found the real cause of the problem:
the program was linked with .NET ( /clr flag enabled ), which is the
default settings in VC7 ( it's called "managed extensions" - very
intuitivie ;) )
Computers which had .NET installed, ran the job without a problem, but
those which didn't have .NET resulted in "wrong binary format" or
something like that, that is, signal 53.
On 1/9/06, Jaime Frey <jfrey@xxxxxxxxxxx> wrote:
On Dec 23, 2005, at 3:36 PM, Mark Silberstein wrote:
> I noticed the following error in my user log.
> ......
> Abnormal termination (signal 53)
> ......
>
> The computer where this error occurs is WinXP SP2.
> Any ideas what this means?
Probably, it just means that the job exited with signal 53. I don't
know what that signal means.
+--------------------------------+-----------------------------------+
|