On Tuesday, 31 January, 2012 at 2:56 PM, slebodnik wrote:
Are symptoms similar like in ticketRegards,LukasOn Tue, 31 Jan 2012 13:39:26 -0500, Ian Chesal<ichesal@xxxxxxxxxxxxxxxxxx> wrote:It seems like it should work but in my 7.6.5 pool any machine that'shibernated by third party (external to Condor) power managementsoftware fails to end up with an OFFLINE=True attribute in themachinead at the collector and subsequently disappears from my list ofmachines so it cannot be woken up by Rooster.Condor appears to know that it's being hibernated. I see thefollowing the MasterLog for the machine when the third party toolstarts the machine hibernation procedure:01/26/12 09:17:13 PowerEventHander: Some driver/application is askingif we can enter hibernation01/26/12 09:17:15 PowerEventHander: Machine entering hibernationLooking through the source it doesn't appear that the event handlerfor this event does anything. There's no sign that it's updating themachine ad to let the collector know it's going offline. When thecollector-side OfflineCollectorPlugin runs the ad is purged, not offlined. If I set the offline attribute on the machine ad to truebeforehibernating the machine by hand everything works. Unfortunately Idon't seem to be able to run a script from the hibernation toolthat'sin use, so I can't (at least not without great difficulty) followthisapproach in the third party tool.Is it not possible to have this third party hibernation offline themachine ad when the hibernate signal is trapped?(This is on Windows BTW…)Regards,- Ian---Ian ChesalCycle Computing, LLCLeader in Open Compute Solutions for Clouds, Servers, and DesktopsEnterprise Condor Support and Management Tools