Todd just reminded me - There was a bug in all versions of Condor
prior to 7.6 where if you restarted condor while a user was logged
on, the KBDD would not restart and would not know how to talk to the
restarted Condor daemons, so it would cease to work until you logged
off and back on again. So the matrix is: For all versions of Condor before 7.4.4 Use the MSI installer and the KBDD will work until you restart Condor then it will fail until you logoff and back on. For Condor 7.4.4 until 7.6.0 Use the MSI installer _or_ add KBDD to the DAEMON_LIST and KBDD will work until you restart (see above). For Condor 7.6.0 and later Use the MSI installer _or_ add KBDD to the DAEMON_LIST, there are no known bugs with the KBDD -tj On 7/7/2011 2:17 AM, Greg.Hitchen@xxxxxxxx wrote:
|